laboratory equipment ( AE-AA990)

laboratory equipment ( AE-AA990)
Product Detailed
1,laboratory equipment,Atomic Absorption Spectrometer, 2,measure total dissolved solids and temperature value of liquids 3,AAS

A & E Lab. 

Main Products: Atomic Absorption Spectrometer (AAS), Fluorescence Spectrophotometer, 

Bio-Spectrophotometer, UV Vis Spectrophotometer, Visible Spectrophotometer, Flame Photometer, 

Whiteness Meter, Turbidity Meter, Colorimeter, Gloss Meter, Tintometer, Automatic Polarimeter, 

Auto Melting Point Apparatus, Automatic Refractometer, Abbe Refractometer, PH/DDS/TDS Meter, etc.

Features: 

Fully Automated

² The flame and graphite furnace is integrated into one instrument.The change over from one technique to another is 

   carried out by simple key strokes within the software.

² The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and 

   optimisation of each hollow cathode lamp by the software.

² The control of the gas flows for the fuel gas (C2H2 ) and the positioning of the bumer is also carried out directly from 

   the software thus allowing optimization of the instruments for the best analytical parameter for a selected analysis.

² Two methods of background correction are available.The first utilises a deuterium lamp and the second is the proven 

   method of self reversal.

² The location of the wavelength and peak selection is automatic and controlled from the software. The spectral 

    bandwidth is automated and is available with a choice of five slit sizes.

² The electronic parameters for the photomultiplier detector,the hollow cathode lamp current and the balancing of the 

    absorbance and background energies are controlled from the software.

² The igntion of the flame is computer controlled and the various safety interlocks offer a very safe operating system.

Technical Specifications:

Model

AE-AA990

 Optic System

Wavelength Range

190nm-900nm

Monochromator 

Czemy-Turner Configuration

 Spectral Bandwidth 

0.1nm,0.2nm,0.4nm,1.0nm,2.0nm(5steps.

with automatic change over)

Wavelength Accuracy

   ±0.25nm

Wavelength Repeatability 

   0.15nm

Baseline Stability 

0.005A/30min